dc.description.abstractDue to its relatively lower thermal conductivity, the suitability of wood is called into question when selecting the flooring material best suited to radiant heating systems. The European standard EN 1264 considers floorings with a thermal resistance over 0.15 m2 K/W to be out of scope. This belief was partially disproved in a previous article that studied wooden floors for Madrid’s climate. However, the effect of climate still needs to be addressed. The present study extends the previous research to worldwide climates and aimed to answer the following questions: (1) Do the lowest thermal conductivity woods present good thermal performance when used in radiant floors? (2) Should the flooring have a maximum thermal resistance value? (3) Is the standard thermal resistance limit of 0.15 m2 K/W objectively justified? And (4) Do the answers of the preceding questions depend on the climate and the construction characteristics? To answer these questions, 28 cities were selected according to the Köppen–Geiger climate classification. In each city, 216 different dwellings were simulated with 60 wood floorings and one of low thermal resistance as a reference, comprising a total of 368,928 cases. Thermal performance was evaluated in terms of three parameters: energy demand, thermal comfort, and start-up lag time. Consequently, the answers to the previous questions were: (1) The lowest thermal conductivity woods can be used efficiently worldwide in radiant floor heating systems with start-up lag times close to that of the reference flooring; (2) There is no limit value for thermal resistance for floorings that can be applied to all dwellings and climates; (3) No objective justification was found for establishing a thermal resistance limit for flooring of 0.15 m2 K/W; and (4) Climate and construction characteristics can play an important role in the correct selection of flooring properties, especially in severe winters and dwellings with the greatest outdoor-exposed envelope and the worst insulation.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourceAppl. Sci. 2022, 12, 5427es_ES
dc.subjectwooden radiant floors worldwidees_ES
dc.subjectenergy efficiency of buildingses_ES
dc.subjectthermal comfortes_ES
dc.subjecteffect of thermal properties of woodes_ES
dc.subjectnatural stone vs. wooden radiant floorses_ES
dc.titleEffect of Wood Properties and Building Construction on Thermal Performance of Radiant Floor Heating Worldwidees_ES