Standard Non-Personalized Electric Field Modeling of Twenty Typical tDCS Electrode Configurations via the Computational Finite Element Method: Contributions and Limitations of Two Different Approaches

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/27497

DOI: 10.3390/biology10121230

ISSN: 2079-7737

Ficheros
SC_2021_724.pdf (19.77Mb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
Molero-Chamizo, Andrés; Nitsche, Michael A.; Gutiérrez Lérida, Carolina; Salas Sánchez, Ángeles; Martín Riquel, Raquel; Andújar Barroso, Rafael Tomás; Alameda-Bailén, José Ramón; García Palomeque, Jesús CarlosAutoridad UCA; Nathzidy Rivera-Urbina, Guadalupe
Fecha
2021-12
Departamento/s
Anatomía Patológica, Biología Celular, Histología, Historia de la Ciencia, Medicina Legal y Forense y Toxicología
Fuente
Biology, Vol. 10, Núm. 12
Resumen
The magnitude, distribution, and characteristics of the electric field induced in the brain by application of transcranial electric stimulation depend on the electrode configuration used and the specific parameters of stimulation. An approach to calculate the generated electric field is the computational finite element method. This method enables simulation of the current spread and electric field strength according to the electrode configuration and stimulation parameters used. However, current approaches have several limitations, which constrain the application of tDCS in empirical research and clinical practice. In this study, we provide examples of standard model-based electric field simulations corresponding to motor, dorsolateral prefrontal, and posterior parietal cortex stimulation using twenty typical electrode configurations. Two different current flow-modeling tools were used to compare the results and determine possible differences between both procedures regarding the specificity, as well as the reliability of the estimates. The results were rather consistent between both simulations. Some modest differences of the simulated distribution and intensity of the electric fields between the results of the respective modeling approaches were identified, which might have functional significance and reveal the need to empirically validate these models. The non-availability of quantitative data about the precise electric field distribution beyond the cortical target is a common limitation of both methods, which limits the determination of the spatial specificity of the intervention. These findings help to define future directions of research that allow to exploit the full potential of standard simulation approaches in the field of non-invasive brain stimulation. Transcranial direct current stimulation (tDCS) is a non-invasive brain stimulation procedure to modulate cortical excitability and related brain functions. tDCS can effectively alter multiple brain functions in healthy humans and is suggested as a therapeutic tool in several neurological and psychiatric diseases. However, variability of results is an important limitation of this method. This variability may be due to multiple factors, including age, head and brain anatomy (including skull, skin, CSF and meninges), cognitive reserve and baseline performance level, specific task demands, as well as comorbidities in clinical settings. Different electrode montages are a further source of variability between tDCS studies. A procedure to estimate the electric field generated by specific tDCS electrode configurations, which can be helpful to adapt stimulation protocols, is the computational finite element method. This approach is useful to provide a priori modeling of the current spread and electric field intensity that will be generated according to the implemented electrode montage. Here, we present standard, non-personalized model-based electric field simulations for motor, dorsolateral prefrontal, and posterior parietal cortex stimulation according to twenty typical tDCS electrode configurations using two different current flow modeling software packages. The resulting simulated maximum intensity of the electric field, focality, and current spread were similar, but not identical, between models. The advantages and limitations of both mathematical simulations of the electric field are presented and discussed systematically, including aspects that, at present, prevent more widespread application of respective simulation approaches in the field of non-invasive brain stimulation.
Materias
current flow; current intensity; electric field; finite element method; tDCS
Colecciones
  • Artículos Científicos [12059]
  • Articulos Científicos Anat. Pat. [109]
Atribución 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Atribución 4.0 Internacional

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario