• español
    • English
  • Login
  • español 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Comunidades y colecciones
Ver ítem 
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Experimental adjustment of the turbulent Schmidt number to model the evaporation rate of swimming pools in CFD programmes

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/27882

DOI: 10.1016/j.csite.2022.102665

ISSN: 2214-157X

Ficheros
APC_2022_144.pdf (2.284Mb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
Foncubierta Blázquez, Juan LuisAutoridad UCA; Rodríguez Maestre, IsmaelAutoridad UCA; González Gallero, Francisco JavierAutoridad UCA; Pérez-Lombard, L.; Bottarelli, Michele
Fecha
2023-01
Departamento/s
Física Aplicada; Máquinas y Motores Térmicos
Fuente
Case Studies in Thermal Engineering, Vol. 41
Resumen
Water evaporation rate is among the most significant parameters to design and select air con-ditioning systems in buildings with indoor swimming pools. Experimental correlations are today widely used to estimate water evaporation rate, although discrepancies of up to 80% among existing correlations have been shown. An alternative to these empirical methods is the calcu-lation of evaporation rate through computer fluid dynamics techniques. One of the most signif-icant parameters to solve the mass transfer at the air-water interface in these models is the value of the turbulent Schmidt number. Although this value depends on air and water conditions (i.e., temperatures, velocities, and vapour pressure, among others), commercial computer fluid dy-namics programmes set a fixed value by default. This study presents a new value through an experimental adjustment. A total of 40 experimental tests have been performed in a wind tunnel under typical conditions in indoor swimming pools. Afterwards, the adjustment was validated with data from 145 experimental tests reported in the scientific literature. The mean relative error in the evaporation rate using the turbulent Schmidt number was 7%, as against 25% using the value by default. The maximum error was reduced from 35% to 15% in forced convection regime.
Colecciones
  • Artículos Científicos [12059]
  • Articulos Científicos Fis. Ap. [318]
  • Articulos Científicos Maq. Mot. Térm. [109]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario