• español
    • English
  • Login
  • español 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Comunidades y colecciones
Ver ítem 
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Inactivation efficacy and reactivation of fecal bacteria with a flow-through LED ultraviolet reactor: Intraspecific response prevails over interspecific differences

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/27946

DOI: 10.1016/j.jwpe.2023.103497

ISSN: 2214-7144

Ficheros
APC_2023_005.pdf (779.8Kb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
Romero Martínez, LeonardoAutoridad UCA; Duque-Sarago, Paola; González-Martín, Claudia; Moreno Andrés, JavierAutoridad UCA; Acevedo Merino, AsunciónAutoridad UCA; Nebot Sanz, EnriqueAutoridad UCA
Fecha
2023-04
Departamento/s
Tecnologías del Medio Ambiente
Fuente
Journal of Water Process Engineering, Vol. 52
Resumen
Treatment with ultraviolet (UV) light is a common option for inactivating waterborne organisms. The mercury vapor lamps conventionally used as a source of UV-C light for water disinfection are eventually replaced by light emitter diodes (LEDs) in the middle term due to their higher efficiency and lack of hazardous materials. Nonetheless, biological mechanisms for repairing UV damage caused by the UV treatment are some of its significant undesirable features. The objective of this study is to evaluate and compare the UV-resistance and the reactivation degree in different strains of E. coli and E. faecalis treated with a flow-through reactor equipped with LEDs with an emission range between 265 and 285 nm. The treated organisms were subjected to various illumination regimes after the UV irradiation. The results obtained indicated that intraspecific differences between the strains of E. coli were greater than the interspecific differences with respect to E. faecalis in terms of UV-resistance and repairing potential. The UV doses necessary to achieve four log-reductions ranged from 10.2 to 16.3 mJ cm−2 for E. coli and from 11.1 to 11.4 for mJ cm−2 for E. faecalis. Dark repair was not observed within 24 h after the UV irradiation whereas the degree of photorepair depended on both the bacteria strain and the applied UV dose. The exposure of the irradiated organisms to an illuminated environment entailed and increasing between the 18 % and the 160 % of the UV dose required to achieve four log-reductions. © 2023 The Author(s)
Materias
Water disinfection; Ultraviolet inactivation; Light emitting diodes (LEDs); Photoreactivation; Fecal bacteria
Colecciones
  • Artículos Científicos [12014]
  • Artículos Científicos INMAR [1043]
  • Articulos Científicos Tec. Med. Amb. [215]
Atribución 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Atribución 4.0 Internacional

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario