Bulk Modification of Sonogel–Carbon with Polyaniline: A Suitable Redox Mediator for Chlorophenols Detection
by Paloma Calatayud-Macías,David López-IglesiasORCID,Alfonso Sierra-PadillaORCID,Laura Cubillana-Aguilera *ORCID,José María Palacios-Santander *ORCID andJuan José García-GuzmánORCID
Department of Analytical Chemistry, Institute of Research on Electron Microscopy and Materials (IMEYMAT), Faculty of Sciences, Campus de Excelencia Internacional del Mar (CEIMAR), University of Cadiz, Campus Universitario de Puerto Real, Polígono del Río San Pedro S/N, 11510 Puerto Real, Spain
*
Authors to whom correspondence should be addressed.
Chemosensors 2023, 11(1), 63; https://doi.org/10.3390/chemosensors11010063
Received: 7 December 2022 / Revised: 10 January 2023 / Accepted: 12 January 2023 / Published: 13 January 2023
(This article belongs to the Special Issue Recent Developments in Electrochemical Sensing)
Download Browse Figures Versions Notes
Abstract
In this work, the development and characterization of a new ceramic material modified with polyaniline powder obtained by a high-power ultrasound sol-gel route is presented. A preliminary screening of the conducting polymer electroactivity was performed by means of cyclic voltammetry in free analyte solution. Remarkable figures of merit for 4-chloro-3-methylphenol (PCMC) determination, selected as the model organic analyte, was obtained with the developed material: the sensitivity and the limit of detection were 2.40 μA/μM·cm2 and 0.69 μM, respectively. The developed device was also successfully applied in the electrochemical determination of PCMC in water samples collected from different sources, obtaining recovery values ranging from 92% to 105%. The electrochemical performance of the device for the detection of other chlorophenols of interest was better in comparison with the bare electrode in all cases, due to the presence of the bulk modifier in the material. Therefore, the electrode material can be promoted for electrochemical assays of different chlorophenols in buffer and real water media for environmental monitoring.
Subjects
Sonogel–Carbon; polyaniline; bulk modifier; 4-chloro-3-methylphenol; spiked waterCollections