• español
    • English
  • Login
  • español 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Comunidades y colecciones
Ver ítem 
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

An experimental and computational approach to thermoelectric-based conditioned mattresses

Identificadores

URI: http://hdl.handle.net/10498/30828

DOI: 10.1016/J.APPLTHERMALENG.2018.02.084

ISSN: 1359-4311

Ficheros
Acceso cerrado (1.065Mb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
Rincón Casado, AlejandroAutoridad UCA; Martínez, A.; Araiz, M.; Pavón Domínguez, PabloAutoridad UCA; Astrain, D.
Fecha
2018-02-23
Departamento/s
Ingeniería Mecánica y Diseño Industrial
Fuente
Applied Thermal Engineering, Vol. 135, 2018, pp. 472-482
Resumen
This paper sets out to describe the design, construction and testing of a thermoelectric-based conditioned mattress intended to reduce the human-mattress interface temperature, in order to increase the user’s sleep quality and thermal comfort in warm locations of Spain. A prototype is constructed and tested, which includes a mattress and a thermoelectric system that cools the inner air and governs the human-mattress interface temperature. This temperature results 2.1 °C lower than that of the room ambient, for 90 W of supplied electric power to the thermoelectric modules, with a coefficient of performance of 0.34. Under this scenario, the comfort perceived by the user is expected to improve compared to that provided by a no-conditioned mattress. The prototype is modified so that the inner air is pumped directly to the human body. With this improvement, the relevant temperature is now that of the inner air, which results 3.4 °C lower than the room ambient temperature, thus expected to increase even more the comfort perceived by the user, with 0.58 of coefficient of performance. In order to simulate both the transient and steady state of the global system, a lumped-capacitance model is devised specifically for this application. The validation process is conducted comparing simulated and experimental values of electric current, temperature difference between ends of the modules, temperature difference between the inner air and the ambient, and coefficient of performance. In steady state, the theoretical model predicts the experimental results with deviations below ±9%. Computational results indicate that the inner air temperature increases by only 1 °C, when air humidity increases from zero to 100%. Under the 100%-humidity scenario, the inner air temperature is still 2.4 °C lower than the room ambient temperature, reducing slightly the coefficient of performance to 0.47.
Materias
Sleep comfort; Air conditioned mattress; Peltier effect; Dynamic simulation; Experimental testing; Relative humidity
Colecciones
  • Artículos Científicos [12006]
  • Articulos Científicos Ing. Mec. [325]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario