• español
    • English
  • Login
  • español 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Comunidades y colecciones
Ver ítem 
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Ionic liquid solvent bar micro-extraction of CdCln(n-2)- species for ultra-trace Cd determination in seawater

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/32455

DOI: 10.1016/j.chemosphere.2017.11.004

ISSN: 0045-6535

ISSN: 1879-1298

Ficheros
chemosphere.pdf (875.2Kb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
Herce Sesa, BelénAutoridad UCA; López López, José AntonioAutoridad UCA; Moreno Aguilar, CarlosAutoridad UCA
Fecha
2018
Departamento/s
Química Analítica
Resumen
Water analysis of trace metals has been benefited by recent studies on sample preparation by liquid micro-extraction. However, there are still limitations for its application to seawater, such as the need of additives to preserve the sample or the availability of chemical extractants for the selective extraction from highly saline samples. In this work, a three phase solvent bar micro-extraction (3SBME) system containing the ionic liquid trioctylmethylammonium chloride (Aliquat® 336) has been used for isolation and pre-concentration of Cd from seawater samples, due to its ability for ionic exchange of CdCln(n−2)-. The system was optimized to work at the natural pH of seawater, and conditions for application to real samples were 0.18 M Aliquat® 336 dissolved in kerosene with 0.25 M dodecan-1-ol as organic solution, 1.5 M HNO3 as acceptor solution, 60 min extraction time, and 800 rpm stirring speed in the sample. Loss of organic solution into the sample during extraction was evaluated and revealed its dependence on stirring rate and extraction time. Under optimum conditions samples containing Cd 0.09–0.90 nM were pre-concentrated 65 times. GF-AAS was used for metal quantification with a limit of detection of 0.04 nM. Accuracy was successfully evaluated measuring Cd in a seawater certified reference material BCR-403.
Materias
Solvent bar micro-extraction; cadmium; ultra-trace analysis; seawater; ionic liquid; hollow fiber
Colecciones
  • Artículos Científicos [12006]
  • Articulos Científicos Quim. Ana. [398]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario