• español
    • English
  • Login
  • español 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Comunidades y colecciones
Ver ítem 
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Ionic liquid based solvent micro-extraction of Ag and Cd from saline and hypersaline waters

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/32457

DOI: 10.1016/j.cej.2016.09.095

ISSN: 1385-8947

Ficheros
1-s2.0-S1385894716313390-main.pdf (526.1Kb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
Herce Sesa, BelénAutoridad UCA; López López, José AntonioAutoridad UCA; Pinto Ganfornina, Juan JoséAutoridad UCA; Moreno Aguilar, CarlosAutoridad UCA
Fecha
2017
Departamento/s
Química Analítica
Resumen
Cadmium (Cd) and silver (Ag) are naturally occurring metals in saline natural waters, which may present toxic effects even at trace level. Membrane technology has been widely applied for their extraction, including hollow fiber supported liquid membranes. However, their application to saline waters is limited. In this work, a hollow fiber liquid micro-extraction system, with a configuration of 2 phase solvent bar micro-extraction (2SBME), using the ionic liquid N-methyl-N,N,N-trioctylammonium chloride (Aliquat® 336), dissolved in kerosene as extractant is proposed to overcome the limitations of existing HFLPME of Ag and Cd in saline waters. The use of an ionic liquid solution in the 2SBME leaded to higher stability of the organic solution in the fiber. The effect of chemical variables on the extraction was evaluated. Extraction of Cd and Ag with Aliquat® 336 was enhanced by Cl- in the sample, but it was independent of the concentration of organic matter. Extraction yield varied in the range 65-80% for Ag, and 45%-95% for Cd, depending on the salinity of samples. The highest extraction was obtained in seawater samples for 75% Aliquat® 336 dissolved in kerosene with 10% dodecan-1-ol, after 45 minutes, and 800 rpm stirring rate in the sample. Efficacy of the proposed system when applied to real samples was 88.10±4.14% for Cd, and 61.47±3.00% for Ag in seawater, and 92.73±5.37% for Cd and 64.23±2.85% for Ag in a hyper-saline lagoon (70 g L-1 NaCl). In conclusion, the proposed methodology allowed a miniaturization of Ag and Cd extraction in short times, requiring lower amount of reagents and solvents, less energy as well as reducing operational cost and wastes if compared with existing liquid membrane based methods.
Materias
silver; cadmium; seawater; hyper-saline waters; ionic liquid,; solvent bar extraction
Colecciones
  • Artículos Científicos [12009]
  • Articulos Científicos Quim. Ana. [398]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario