A spiral flowing supported liquid membrane based on DEHPA carrier for the separation of lead from seawater.

Identificadores
URI: http://hdl.handle.net/10498/32914
DOI: https://doi.org/10.1080/19443994.2015.1004199
ISSN: 1944-3994
ISSN: 1944-3986
Ficheros
Estadísticas
Métricas y Citas
Metadatos
Mostrar el registro completo del ítemFecha
2015Departamento/s
Química AnalíticaFuente
Desalination and Water Treatment 57-13, pp.5715-5722.Resumen
This work aims to study the use of a spiral supported liquid membrane (SLM) to extract lead (Pb) from seawater matrix using the di-(2-ethylhexyl) phosphoric acid (DEHPA) dissolved in kerosene as carrier. In this regard, several physical and chemical parameters which could affect Pb extraction (sample pH, sodium acetate buffer, HNO3 concentration in stripping solution, masking agent effect, flow rate, filter porosity, and configuration of the SLM cell) were studied. In this sense, the permeability parameter was selected to probe the system efficiency. The optimal preconcentration factor was found to be of 14.2, after 2 h under the following conditions: sample pH equal to 4.7 buffered until a 0.08 M of sodium acetate, DEPHA concentration fixed at 0.21 M and HNO3 concentration of 0.23 M in stripping solution. Besides, SLM filters were analyzed by electron microscopy after each period of 2 h and several microparticles and other deposits in form of a thin layer were observed in the polymeric support.
Materias
Spiral supported liquid membrane; Lead; Seawater; Pre-concentration; ExtractionColecciones
- Artículos Científicos [12034]
- Articulos Científicos Quim. Ana. [398]