• español
    • English
  • Login
  • English 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Communities and Collections
View Item 
  •   RODIN Home
  • Producción Científica
  • Artículos Científicos
  • View Item
  •   RODIN Home
  • Producción Científica
  • Artículos Científicos
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

A Dual Monitoring Technique to Detect Power Quality Transients Based on the Fourth-Order Spectrogram

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/35175

DOI: 10.3390/en11030503

ISSN: 1996-1073

Files
Artículo publicado (1.164Mb)
Statistics
View statistics
Metrics and citations
 
Share
Export
Export reference to MendeleyRefworksEndNoteBibTexRIS
Metadata
Show full item record
Author/s
González de la Rosa, Juan JoséAuthority UCA; Agüera Pérez, AgustínAuthority UCA; Palomares Salas, José CarlosAuthority UCA; Florencias Oliveros, OliviaAuthority UCA; Sierra Fernández, José MaríaAuthority UCA
Date
2018-02-27
Department
Ingeniería en Automática, Electrónica, Arquitectura y Redes de Computadores
Source
Energies 2018, 11(3)
Abstract
This paper presents a higher-order statistics-based approach of detecting transients that uses the fourth-order discrete spectrogram to monitor the power supply in a node of the domestic smart grid. Taking advantage of the mixed time–frequency domain information, the method allows for the transient detection and the subsequent identification of the potential area in which the fault takes place. The proposed method is evaluated through real power-line signals from the Spanish electrical grid. Thanks to the peakedness enhancement capability of the higher-order spectra, the results show that the procedure is able to detect low-level transients, which are likely ignored by the traditional detection procedures, where the concern pertains to power reliability (not oriented to micro grids), and this, by analyzing the duration and frequency content of the electrical perturbation, may indicate prospective faulty states of elements in a grid. Easy to implement in a hand-held instrument, the computational strategy has a 5 Hz resolution in the range 0–500 Hz and a 50 Hz resolution in the range of 0–5 kHz, and could be consequently used by technicians in order to allocate new types of transients originated by the distributed energy resources. Four real-life case-studies illustrate the performance.
Subjects
higher-order statistics; micro grids; power quality (PQ); spectral kurtosis (SK); spectrogram; time–frequency analysis; transient detection
Collections
  • Artículos Científicos [11777]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Browse

All of RODINCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Statistics

View Usage Statistics

Información adicional

AboutDeposit in RODINPoliciesGuidelinesRightsLinksStatisticsNewsFrequently Asked Questions

RODIN is available through

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Academic

Related links

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

Contact informationSuggestionsUser Support