Mostrar el registro sencillo del ítem

dc.contributor.authorGonzález de la Rosa, Juan José 
dc.contributor.authorAgüera Pérez, Agustín 
dc.contributor.authorPalomares Salas, José Carlos 
dc.contributor.authorFlorencias Oliveros, Olivia 
dc.contributor.authorSierra Fernández, José María 
dc.contributor.otherIngeniería en Automática, Electrónica, Arquitectura y Redes de Computadoreses_ES
dc.date.accessioned2025-01-30T15:35:45Z
dc.date.available2025-01-30T15:35:45Z
dc.date.issued2018-02-27
dc.identifier.issn1996-1073
dc.identifier.urihttp://hdl.handle.net/10498/35175
dc.descriptionAuthor Contributions Juan-José González-de-la-Rosa proposed the spectral kurtosis as a tool to monitor PQ events, and designed the experiment and the paper layout; Agustín Agüera-Pérez designed the software and the experiment strategy with José-Carlos Palomares-Salas; Olivia Florencias-Oliveros selected the signals from the database and arranged the instrumentation; José-María Sierra-Fernández contributed to the optimization of the spectral kurtosis.es_ES
dc.description.abstractThis paper presents a higher-order statistics-based approach of detecting transients that uses the fourth-order discrete spectrogram to monitor the power supply in a node of the domestic smart grid. Taking advantage of the mixed time–frequency domain information, the method allows for the transient detection and the subsequent identification of the potential area in which the fault takes place. The proposed method is evaluated through real power-line signals from the Spanish electrical grid. Thanks to the peakedness enhancement capability of the higher-order spectra, the results show that the procedure is able to detect low-level transients, which are likely ignored by the traditional detection procedures, where the concern pertains to power reliability (not oriented to micro grids), and this, by analyzing the duration and frequency content of the electrical perturbation, may indicate prospective faulty states of elements in a grid. Easy to implement in a hand-held instrument, the computational strategy has a 5 Hz resolution in the range 0–500 Hz and a 50 Hz resolution in the range of 0–5 kHz, and could be consequently used by technicians in order to allocate new types of transients originated by the distributed energy resources. Four real-life case-studies illustrate the performance.es_ES
dc.description.sponsorshipThis research was supported by the Spanish Ministry of Economy, Industry and Competitiveness in the work flow of the State Plan of Excellency and Challenges for Research, via the project TEC2016-77632-C3-3-R-COntrol and Management of Isolable NanoGrids: Smart Instruments for Solar forecasting and Energy Monitoring (COMING-SISEM), which involves the development of new measurement techniques applied to monitor the PQ in micro-grids. Additionally, we express our gratitude to the Andalusian Government for funding the Research Group PAIDI-TIC-168 in Computational Instrumentation and Industrial Electronics (ICEI).es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceEnergies 2018, 11(3)es_ES
dc.subjecthigher-order statisticses_ES
dc.subjectmicro gridses_ES
dc.subjectpower quality (PQ)es_ES
dc.subjectspectral kurtosis (SK)es_ES
dc.subjectspectrogrames_ES
dc.subjecttime–frequency analysises_ES
dc.subjecttransient detectiones_ES
dc.titleA Dual Monitoring Technique to Detect Power Quality Transients Based on the Fourth-Order Spectrogrames_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/en11030503
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internacional