• español
    • English
  • Login
  • español 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Comunidades y colecciones
Ver ítem 
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Amperometic microsensor for measurement of gaseous and dissolved CO2

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/35236

DOI: 10.1016/j.snb.2018.12.038

ISSN: 0925-4005

Ficheros
Articulo principal (543.4Kb)
version editor (1.624Mb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
Revsbech, Niels Peter; García Robledo, Emilio GuillermoAutoridad UCA; Sveegaard, S.; Andersen, M.H.; Gothelf, K.V.; Larsen, L.H.
Fecha
2019
Departamento/s
Biología
Fuente
Sensors and Actuators B: Chemical - 2019, Vol. 283, pp. 349-354
Resumen
A simple method to measure dissolved CO2 at a microscale would be beneficial for many scientific and medical applications. A simple amperometic microsensor for CO2 with a 20-100 µm wide tip was developed by placing a layer of acidic O2 trap solution containing Cr2+ in front of a Clark-type electrochemical sensor. The Clark-type sensor contains a Ag cathode in an ionic liquid, and also a Ag guard cathode behind the sensing cathode to prevent interference from reducible contaminants in the ionic liquid. The constructed sensors exhibited linear response over relatively large intervals of CO2 partial pressure, but for CO2 partial pressures of < 20 Pa the response was only about 60% of that observed at 20-1000 Pa. The slope of the calibration curve at 2-6 kPa was about 80% of the slope from 0-1 kPa. A high baseline signal caused by water diffusing through the membrane into the ionic liquid was avoided by making very conical sensors so that the water concentration around the cathode was kept low by diffusional transport into the bulk reservoir of ionic liquid, but elevated zero currents by a factor of about two was often observed for sensors more than 1 month old. The lifetime of the sensor by continuous operation can be more than 4 months, but with a slow decrease in sensitivity that may be caused by lower membrane permeability. Use of the sensor was demonstrated by measuring CO2 dynamics in the thallus of a red algae along with variations in O2 and pH.
Materias
Ionic liquid; Carbon dioxide reduction; Clark electrode; oxygen scavenger
Colecciones
  • Artículos Científicos [12006]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario