Show simple item record

dc.contributor.authorMarín Galindo, Alberto 
dc.contributor.authorOpazo Díaz, Edgardo
dc.contributor.authorRamírez Jiménez, Miguel
dc.contributor.authorMontes de Oca García, Adrian 
dc.contributor.authorCorral Pérez, Juan 
dc.contributor.authorPérez Pérez, Alejandro 
dc.contributor.authorCasals Vázquez, Cristina 
dc.contributor.authorPonce González, Jesús Gustavo 
dc.contributor.otherDidáctica de la Educación Física, Plástica y Musicales_ES
dc.date.accessioned2025-06-10T11:15:30Z
dc.date.available2025-06-10T11:15:30Z
dc.date.issued2025
dc.identifier.issn2666-3376
dc.identifier.urihttp://hdl.handle.net/10498/36492
dc.description.abstractBackground: Measuring maximal fat oxidation (MFO) and maximal oxygen consumption (V_ O2max) typically requires two separate days, which can be time-consuming. This study aimed to assess the validity and reliability of a single-day test for measuring MFO and V_ O2max in individuals with pre-diabetes/type 2 diabetes (T2DM). Methods: Twenty adults with pre-diabetes/T2DM (10 women; [53.1 8.8] years) participated in this crosssectional study. Participants underwent a single-day MFO- V_ O2max protocol, followed by the traditional V_ O2max test on a cycle ergometer 4–7 days later, with both assessments performed using indirect calorimetry. The singleday test commenced with the MFO test, involving 15 W per 3 min increments until the respiratory exchange rate reached 1.0. After a 5-minute (min) rest, the V_ O2max test was conducted, starting at the last load and increasing by 15 W⋅min-1 until voluntary exhaustion. The traditional V_ O2max test involved a 15 W⋅min-1n incremental protocol until voluntary exhaustion, followed by a verification test at 110% of the previous maximum load. Results: No significant differences were observed between MFO-V_ O2max and traditional V_ O2max protocol in V_ O2max values ([2 099.4 534.1] ml⋅min-1 vs. [2 119.1 548.3] ml⋅min-1, p ¼ 0.715) or heart rate ([163.2 18.2] beat/ min vs. [164.5 16.1] beat/min, p ¼ 0.485). The MFO-V_ O2max protocol test demonstrated excellent reliability (intraclass correlation coefficient ¼ 0.957), limits of agreement ranging from 300.06 ml⋅min-1 to 306.77 ml⋅min-1, and the standard error of measurement was 181.67 ml⋅min-1. Conclusions: Therefore, the single-day test is a valid and reliable method for assessing both MFO and V_ O2max in men and women with pre-diabetes/T2DM. With a mean total duration of (34 8) min, this test enhances clinical applicability by significantly reducing the time and cost associated with traditional assessments.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherKeAies_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceSports Medicine and Health Science, 2025es_ES
dc.subjectValidationes_ES
dc.subjectCardiorespiratory fitnesses_ES
dc.subjectFatMaxes_ES
dc.subjectMetabolic flexibilityes_ES
dc.subjectExercise testses_ES
dc.subjectExercise physiologyes_ES
dc.titleValidity and reliability of V˙O2max determination immediately after a maximal fat oxidation assessment in pre-diabetes/type 2 Diabetes Mellitus populationes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doihttps://doi.org/10.1016/j.smhs.2025.02.004
dc.relation.projectID"info:eu-repo\/grantAgreement\/AEI\/Plan Estatal de Investigaci\u00f3n Cient\u00edfica y T\u00e9cnica y de Innovaci\u00f3n 2017-2020\/PID2020-120034RA-I00\/ES\/PAPEL DE UNA ESTRATEGIA EDUCATIVA NUTRICIONAL Y DE EJERCICIO FISICO EN LA REGULACION DEL APETITO Y COMPOSICION CORPORAL EN FUNCION DEL PERFIL DE EXOSOMAS EN DIABETICOS TIPO 2\/"es_ES
dc.type.hasVersionVoRes_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional