| dc.contributor.author | Marín Galindo, Alberto | |
| dc.contributor.author | Opazo Díaz, Edgardo | |
| dc.contributor.author | Ramírez Jiménez, Miguel | |
| dc.contributor.author | Montes de Oca García, Adrian | |
| dc.contributor.author | Corral Pérez, Juan | |
| dc.contributor.author | Pérez Pérez, Alejandro | |
| dc.contributor.author | Casals Vázquez, Cristina | |
| dc.contributor.author | Ponce González, Jesús Gustavo | |
| dc.contributor.other | Didáctica de la Educación Física, Plástica y Musical | es_ES |
| dc.date.accessioned | 2025-06-10T11:15:30Z | |
| dc.date.available | 2025-06-10T11:15:30Z | |
| dc.date.issued | 2025 | |
| dc.identifier.issn | 2666-3376 | |
| dc.identifier.uri | http://hdl.handle.net/10498/36492 | |
| dc.description.abstract | Background: Measuring maximal fat oxidation (MFO) and maximal oxygen consumption (V_ O2max) typically requires two separate days, which can be time-consuming. This study aimed to assess the validity and reliability of a
single-day test for measuring MFO and V_ O2max in individuals with pre-diabetes/type 2 diabetes (T2DM).
Methods: Twenty adults with pre-diabetes/T2DM (10 women; [53.1 8.8] years) participated in this crosssectional study. Participants underwent a single-day MFO- V_ O2max protocol, followed by the traditional V_ O2max
test on a cycle ergometer 4–7 days later, with both assessments performed using indirect calorimetry. The singleday test commenced with the MFO test, involving 15 W per 3 min increments until the respiratory exchange rate
reached 1.0. After a 5-minute (min) rest, the V_ O2max test was conducted, starting at the last load and increasing by
15 W⋅min-1 until voluntary exhaustion. The traditional V_ O2max test involved a 15 W⋅min-1n incremental protocol
until voluntary exhaustion, followed by a verification test at 110% of the previous maximum load.
Results: No significant differences were observed between MFO-V_ O2max and traditional V_ O2max protocol in V_ O2max
values ([2 099.4 534.1] ml⋅min-1 vs. [2 119.1 548.3] ml⋅min-1, p ¼ 0.715) or heart rate ([163.2 18.2] beat/
min vs. [164.5 16.1] beat/min, p ¼ 0.485). The MFO-V_ O2max protocol test demonstrated excellent reliability
(intraclass correlation coefficient ¼ 0.957), limits of agreement ranging from 300.06 ml⋅min-1 to 306.77 ml⋅min-1,
and the standard error of measurement was 181.67 ml⋅min-1.
Conclusions: Therefore, the single-day test is a valid and reliable method for assessing both MFO and V_ O2max in
men and women with pre-diabetes/T2DM. With a mean total duration of (34 8) min, this test enhances clinical
applicability by significantly reducing the time and cost associated with traditional assessments. | es_ES |
| dc.format | application/pdf | es_ES |
| dc.language.iso | eng | es_ES |
| dc.publisher | KeAi | es_ES |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.source | Sports Medicine and Health Science, 2025 | es_ES |
| dc.subject | Validation | es_ES |
| dc.subject | Cardiorespiratory fitness | es_ES |
| dc.subject | FatMax | es_ES |
| dc.subject | Metabolic flexibility | es_ES |
| dc.subject | Exercise tests | es_ES |
| dc.subject | Exercise physiology | es_ES |
| dc.title | Validity and reliability of V˙O2max determination immediately after a maximal fat oxidation assessment in pre-diabetes/type 2 Diabetes Mellitus population | es_ES |
| dc.type | journal article | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.identifier.doi | https://doi.org/10.1016/j.smhs.2025.02.004 | |
| dc.relation.projectID | "info:eu-repo\/grantAgreement\/AEI\/Plan Estatal de Investigaci\u00f3n Cient\u00edfica y T\u00e9cnica y de Innovaci\u00f3n 2017-2020\/PID2020-120034RA-I00\/ES\/PAPEL DE UNA ESTRATEGIA EDUCATIVA NUTRICIONAL Y DE EJERCICIO FISICO EN LA REGULACION DEL APETITO Y COMPOSICION CORPORAL EN FUNCION DEL PERFIL DE EXOSOMAS EN DIABETICOS TIPO 2\/" | es_ES |
| dc.type.hasVersion | VoR | es_ES |