• español
    • English
  • Login
  • English 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Communities and Collections
View Item 
  •   RODIN Home
  • Producción Científica
  • Artículos Científicos
  • View Item
  •   RODIN Home
  • Producción Científica
  • Artículos Científicos
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Validity and reliability of V˙O2max determination immediately after a maximal fat oxidation assessment in pre-diabetes/type 2 Diabetes Mellitus population

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/36492

DOI: https://doi.org/10.1016/j.smhs.2025.02.004

ISSN: 2666-3376

Files
OA_2025_0261.pdf (996.4Kb)
Statistics
View statistics
Metrics and citations
 
Share
Export
Export reference to MendeleyRefworksEndNoteBibTexRIS
Metadata
Show full item record
Author/s
Marín Galindo, AlbertoAuthority UCA; Opazo Díaz, Edgardo; Ramírez Jiménez, Miguel; Montes de Oca García, AdrianAuthority UCA; Corral Pérez, JuanAuthority UCA; Pérez Pérez, AlejandroAuthority UCA; Casals Vázquez, CristinaAuthority UCA; Ponce González, Jesús GustavoAuthority UCA
Date
2025
Department
Didáctica de la Educación Física, Plástica y Musical
Source
Sports Medicine and Health Science, 2025
Abstract
Background: Measuring maximal fat oxidation (MFO) and maximal oxygen consumption (V_ O2max) typically requires two separate days, which can be time-consuming. This study aimed to assess the validity and reliability of a single-day test for measuring MFO and V_ O2max in individuals with pre-diabetes/type 2 diabetes (T2DM). Methods: Twenty adults with pre-diabetes/T2DM (10 women; [53.1 8.8] years) participated in this crosssectional study. Participants underwent a single-day MFO- V_ O2max protocol, followed by the traditional V_ O2max test on a cycle ergometer 4–7 days later, with both assessments performed using indirect calorimetry. The singleday test commenced with the MFO test, involving 15 W per 3 min increments until the respiratory exchange rate reached 1.0. After a 5-minute (min) rest, the V_ O2max test was conducted, starting at the last load and increasing by 15 W⋅min-1 until voluntary exhaustion. The traditional V_ O2max test involved a 15 W⋅min-1n incremental protocol until voluntary exhaustion, followed by a verification test at 110% of the previous maximum load. Results: No significant differences were observed between MFO-V_ O2max and traditional V_ O2max protocol in V_ O2max values ([2 099.4 534.1] ml⋅min-1 vs. [2 119.1 548.3] ml⋅min-1, p ¼ 0.715) or heart rate ([163.2 18.2] beat/ min vs. [164.5 16.1] beat/min, p ¼ 0.485). The MFO-V_ O2max protocol test demonstrated excellent reliability (intraclass correlation coefficient ¼ 0.957), limits of agreement ranging from 300.06 ml⋅min-1 to 306.77 ml⋅min-1, and the standard error of measurement was 181.67 ml⋅min-1. Conclusions: Therefore, the single-day test is a valid and reliable method for assessing both MFO and V_ O2max in men and women with pre-diabetes/T2DM. With a mean total duration of (34 8) min, this test enhances clinical applicability by significantly reducing the time and cost associated with traditional assessments.
Subjects
Validation; Cardiorespiratory fitness; FatMax; Metabolic flexibility; Exercise tests; Exercise physiology
Collections
  • Artículos Científicos [11977]
  • Articulos Científicos Did. E. Fis. [461]
  • Artículos Científicos INIBICA [1093]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Browse

All of RODINCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Statistics

View Usage Statistics

Información adicional

AboutDeposit in RODINPoliciesGuidelinesRightsLinksStatisticsNewsFrequently Asked Questions

RODIN is available through

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Academic

Related links

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

Contact informationSuggestionsUser Support