dc.contributor.authorGarcía Guzmán, Juan José 
dc.contributor.authorPérez Ràfols, Clara
dc.contributor.authorCuartero, María
dc.contributor.authorCrespo, Gastón A.
dc.contributor.otherQuímica Analíticaes_ES
dc.date.accessioned2025-07-08T16:18:48Z
dc.date.available2025-07-08T16:18:48Z
dc.date.issued2021
dc.identifier.issn2379-3694
dc.identifier.urihttp://hdl.handle.net/10498/36661
dc.description.abstractWe present herein the most complete characterization of microneedle (MN) potentiometric sensors for pH transdermal measurements for the time being. Initial in vitro assessment demonstrated suitable analytical performances (e.g., Nernstian slope, linear range of response from 8.5 to 5.0, and fast response time) in both buffer media and artificial interstitial fluid (ISF). Excellent repeatability and reproducibility together with adequate selectivity and resiliency facilitate the appropriateness of the new pH MN sensor for transdermal ISF analysis in healthcare. The ability to resist skin insertions was evaluated in several ex vivo setups using three different animal skins (i.e., chicken, pork, and rat). The developed pH MN sensor was able to withstand from 5 to 10 repetitive insertions in all the skins considered with a minimal change in the calibration graph (<3% variation in both slope and intercept after the insertions). Ex vivo pH measurements were validated by determining the pH with the MN sensor and a commercial pH electrode in chicken skin portions previously conditioned at several pH values, obtaining excellent results with an accuracy of <1% and a precision of <2% in all cases. Finally, pH MN sensors were applied for the very first time to transdermal measurements in rats together with two innovative validation procedures: (i) measuring subcutaneous pH directly with a commercial pH microelectrode and (ii) collecting ISF using hollow MNs and then the pH measurement of the sample with the pH microelectrode. The pH values obtained with pH MN sensors were statistically more similar to subcutaneous measurements, as inferred by a paired sample t-test at 95% of confidence level. Conveniently, the validation approaches could be translated to other analytes that are transdermally measured with MN sensors.es_ES
dc.description.sponsorshipStiftelsen Olle Engkvist Byggmästare (Project Grant 204-0214), and the Novo Nordisk Fonden (Exploratory Pre-Seed Grant 19OC0056171)es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherACSes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceACS Sensors - 2021, Vol 6, pp. 1129-1137es_ES
dc.subjectIon-selective electrodeses_ES
dc.subjectpH sensinges_ES
dc.subjectin vivo monitoringes_ES
dc.subjectmicroneedle transdermal sensinges_ES
dc.subjectvalidationes_ES
dc.titleToward In Vivo Transdermal pH Sensing with a Validated Microneedle Membrane Electrodees_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1021/acssensors.0c02397
dc.type.hasVersionVoRes_ES