• español
    • English
  • Login
  • español 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Comunidades y colecciones
Ver ítem 
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Enhanced CFD-based approach to calculate the evaporation rate in swimming pools

Identificadores

URI: http://hdl.handle.net/10498/38359

DOI: 10.1080/23744731.2020.1868219

ISSN: 2374-4731

Ficheros
Acceso Cerrado (2.689Mb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
González Gallero, Francisco JavierAutoridad UCA; Rodríguez Maestre, IsmaelAutoridad UCA; Foncubierta Blázquez, Juan LuisAutoridad UCA; Mena Baladés, Jesús DanielAutoridad UCA
Fecha
2020
Departamento/s
Física Aplicada; Ingeniería Industrial e Ingeniería Civil; Máquinas y Motores Térmicos
Fuente
Science and Technology for the Built Environment, (2021) vol. 27, nº 4, pp. 524 - 532
Resumen
An improvement of a formerly proposed CFD-based methodology (base model) for the estimation of water evaporation rate in swimming pools is presented here. This base model achieved satisfactorily on average (10% of relative error) under mixed and natural convection, but it deviated from the experimental measurements significantly (up to 45%) for conditions dominated by forced convection. The enhancement of the base model focusses on the adjustment of the air-water shear stress in terms of the average Reynolds number. First, a set of 32 laboratory-scale evaporation experiments under forced convection were carried out optimizing shear stress values toward getting a prescribed target for the evaporation rate estimation. In contrast to the base model, with this adjusted boundary condition the enhanced model gave rate values that fitted quite well (6%) with experimental measurements. Finally, a model validation was also developed by using two sets of experiments provided by the scientific literature. 145 cases were taken into account for which the enhanced model performed very satisfactorily and better on average than the base model (7% and 25% of average relative error, respectively). The improvement was even higher under forced convection prevailing conditions, with relative error of the order of the common experimental measurements.
Materias
Forced convection; Reynolds number; Shear stress; Swimming pools; Average relative error; Evaporation rate
Colecciones
  • Artículos Científicos [11777]

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario