Agreement-Based Validation of ISOMETRO for Upper-Limb Isometric Tension Measurements

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/39008

DOI: 10.3390/s26051504

ISSN: 1424-8220

Ficheros
Artículo principal (5.287Mb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
González Montesinos, José LuisAutoridad UCA; Fernández Santos, Jorge del RosarioAutoridad UCA; Jiménez Pavón, DavidAutoridad UCA; Sánchez Delgado, Alejandro; Aragón Martín, RubénAutoridad UCA; Escudier-Vázquez, Juan Manuel; España Romero, VanesaAutoridad UCA
Fecha
2026-02-27
Departamento/s
Didáctica de la Educación Física, Plástica y Musical
Fuente
Sensors - 2026, 26(5), 1504.
Resumen
Muscular fitness is a key component of health and athletic performance, and isometric strength is a widely used indicator. This study reports an agreement-based validation of the Isometric Strength Measurement Device (ISOMETRO) for upper-limb isometric tension measurements under controlled laboratory conditions. Twenty-one healthy young amateur rock climbers (11 men and 10 women) performed four upper-limb tensile tests (shoulder adduction at 90°, shoulder adduction at 60°, shoulder extension at 90°, and elbow extension at 90°). Agreement with an independent criterion device was evaluated using a force plate, while a series-connected load cell was used as an internal consistency check of the measurement chain. Linear mixed-effects models showed that ISOMETRO strongly predicted force plate values (β = 0.999, SE = 0.002, p < 0.001), with a marginal R2 > 0.99. Bland–Altman analysis indicated negligible bias (−0.08 N) and narrow limits of agreement (−4.97 to 4.81 N), and concordance was excellent (CCC ≥ 0.996). The series-connected load cell comparison also showed near-unity agreement (β = 0.998, SE = 0.003, p < 0.001), supporting internal measurement chain integrity. These findings support excellent agreement between ISOMETRO and force plate measurements for upper-limb tensile isometric testing along the vertical axis in young amateur rock climbers under controlled laboratory conditions. However, given the specific sample characteristics and the strictly vertical laboratory configuration, these results should not be generalized to other populations, joint angles, force directions, or non-laboratory environments without further validation. Further studies are needed to confirm performance in more diverse contexts and to establish reliability for repeated-measurement applications.
Materias
isometric force; isometric strength; agreement analysis; criterion agreement; force plate; load cell; measurement chain; muscular strength; exercise testing; biomechanics; biomedical sensors
Colecciones
  • Artículos Científicos [11595]
Attribution 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution 4.0 Internacional

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario