Assessing the impact of courtyards in cooling energy demand in buildings

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/25867

DOI: 10.1016/j.jclepro.2021.128742

ISSN: 0959-6526

ISSN: 1879-1786 (internet)

Files
2021_777.pdf (11.88Mb)
Statistics
View statistics
Metrics and citations
 
Share
Export
Export reference to MendeleyRefworksEndNoteBibTexRIS
Metadata
Show full item record
Author/s
Sánchez de la Flor, Francisco JoséAuthority UCA; Ruiz Pardo, ÁlvaroAuthority UCA; Diz Mellado, Eduardo MaríaAuthority UCA; Rivera-Gómez, Carlos; Galán-Marín, Carmen
Date
2021-10
Department
Máquinas y Motores Térmicos
Source
Journal of Cleaner Production 320 (2021) 128742
Abstract
Sustainable passive design strategies can reduce the energy consumption of buildings. In this regard, inner courtyards act as microclimate modifiers that enhance the perception of comfort in the surrounding environment. The present study, through a pooled analysis of experimental and numerical data, intends to assess the beneficial effect that the courtyards have in reducing the energy consumption of the buildings, especially for cooling demand. Accordingly, a new methodology allowing the use of different experimental data for facades and courtyards in software tools for the assessment of the real energy performance of buildings with courtyards is proposed. Besides, a detailed example of the application of the proposed methodology is performed for two scenarios simultaneously: a case study (considering the courtyard effect on the air temperature) and a reference one (without considering this effect). From the results, it is found that the courtyard reduces the demand for cooling in the spaces bordering it. As expected, the magnitude of the cooling demand reduction is correlated to the floor level, is increased at lower floors in the courtyard building. This relative reduction is up to 11%, being, for the case study analyzed, an average reduction of 7%.
Subjects
Building performance simulation; Building energy modelling (BEM); Building energy demand; Passive cooling; Inner courtyards; Simulation tools
Collections
  • Artículos Científicos [11777]
  • Articulos Científicos Maq. Mot. Térm. [108]
Atribución 4.0 Internacional
This work is under a Creative Commons License Atribución 4.0 Internacional

Browse

All of RODINCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Statistics

View Usage Statistics

Información adicional

AboutDeposit in RODINPoliciesGuidelinesRightsLinksStatisticsNewsFrequently Asked Questions

RODIN is available through

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Academic

Related links

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

Contact informationSuggestionsUser Support