Assessing the impact of courtyards in cooling energy demand in buildings

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/25867

DOI: 10.1016/j.jclepro.2021.128742

ISSN: 0959-6526

ISSN: 1879-1786 (internet)

Ficheros
2021_777.pdf (11.88Mb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
Sánchez de la Flor, Francisco JoséAutoridad UCA; Ruiz Pardo, ÁlvaroAutoridad UCA; Diz Mellado, Eduardo MaríaAutoridad UCA; Rivera-Gómez, Carlos; Galán-Marín, Carmen
Fecha
2021-10
Departamento/s
Máquinas y Motores Térmicos
Fuente
Journal of Cleaner Production 320 (2021) 128742
Resumen
Sustainable passive design strategies can reduce the energy consumption of buildings. In this regard, inner courtyards act as microclimate modifiers that enhance the perception of comfort in the surrounding environment. The present study, through a pooled analysis of experimental and numerical data, intends to assess the beneficial effect that the courtyards have in reducing the energy consumption of the buildings, especially for cooling demand. Accordingly, a new methodology allowing the use of different experimental data for facades and courtyards in software tools for the assessment of the real energy performance of buildings with courtyards is proposed. Besides, a detailed example of the application of the proposed methodology is performed for two scenarios simultaneously: a case study (considering the courtyard effect on the air temperature) and a reference one (without considering this effect). From the results, it is found that the courtyard reduces the demand for cooling in the spaces bordering it. As expected, the magnitude of the cooling demand reduction is correlated to the floor level, is increased at lower floors in the courtyard building. This relative reduction is up to 11%, being, for the case study analyzed, an average reduction of 7%.
Materias
Building performance simulation; Building energy modelling (BEM); Building energy demand; Passive cooling; Inner courtyards; Simulation tools
Colecciones
  • Artículos Científicos [11777]
  • Articulos Científicos Maq. Mot. Térm. [108]
Atribución 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Atribución 4.0 Internacional

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario