• español
    • English
  • Login
  • español 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Comunidades y colecciones
Ver ítem 
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Simplified model of battery energy-stored quasi-Z-source inverter-based photovoltaic power plant with Twofold energy management system

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/26321

DOI: 10.1016/j.energy.2021.122563

ISSN: 0360-5442

Ficheros
APC_2021_049.pdf (2.405Mb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
De Oliveira-Assis, Lais; Soares-Ramos, Emanuel P. P.; Sarrias Mena, RaúlAutoridad UCA; Sarrias Mena, RaúlAutoridad UCA; García Triviño, PabloAutoridad UCA; González Rivera, EnriqueAutoridad UCA; Sánchez Sainz, HiginioAutoridad UCA; Llorens Iborra, FranciscoAutoridad UCA; Fernández Ramírez, Luis MiguelAutoridad UCA
Fecha
2022-04
Departamento/s
Ingeniería Eléctrica; Ingeniería en Automática, Electrónica, Arquitectura y Redes de Computadores
Fuente
Energy 244 (2022) 122563
Resumen
The use of a battery energy-stored quasi-Z-source inverter (BES-qZSI) for large-scale PV power plants exhibits promising features due to the combination of qZSI and battery as energy storage system, such as single-stage power conversion (without additional DC/DC boost converter), improvements in the output waveform quality (due to the elimination of switching dead time), and continuous and smooth delivery of energy to the grid (through the battery energy storage system). This paper presents a new simplified model of a BES-qZSI to represent the converter dynamics with sufficient accuracy while using a less complex model than the detailed model (including the modelling of all switches and switching pulses). It is based on averaged values of the variables, voltage/current sources, and the same control circuit than the detailed model, except for the switching pulses generation. The simplified model enables faster time-domain simulation and is useful for control design and dynamic analysis purposes. Additionally, an energy management system has been developed to govern the power supply to grid under two possible scenarios: 1) System operator command following; or 2) economic dispatch of the stored energy. The results obtained from simulations and experimental hardware-in-the-loop (HIL) setup for different operating conditions of the grid-connected large-scale PV power plant with battery energy storage under study demonstrate the validity of the proposed simplified model to represent the dynamics of the converter and PV power plant for steady-state stability studies, long-term simulations, or large electric power systems. © 2021 The Authors
Materias
PV power Plant; Energy storage system; Quasi-Z-source inverter; Modelling Control
Colecciones
  • Artículos Científicos [11595]
  • Articulos Científicos Ing. Elec. [76]
  • Articulos Científicos Ing. Sis. Aut. [180]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario