• español
    • English
  • Login
  • English 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Communities and Collections
View Item 
  •   RODIN Home
  • Producción Científica
  • Artículos Científicos
  • View Item
  •   RODIN Home
  • Producción Científica
  • Artículos Científicos
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Reducing the Cooling Energy Demand by Optimizing the Airflow Distribution in a Ventilated Roof: Numerical Study for an Existing Residential Building and Applicability Map

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/34751

DOI: 10.3390/APP14156596

ISSN: 2076-3417

Files
2024 Reducing the Cooling Energy Demand by Optimizing the Airflow Distribution in a Ventilated Roof.pdf (40.03Mb)
Statistics
View statistics
Metrics and citations
 
Share
Export
Export reference to MendeleyRefworksEndNoteBibTexRIS
Metadata
Show full item record
Author/s
Rincón Casado, AlejandroAuthority UCA; Rodríguez Jara, Enrique ÁngelAuthority UCA; Ruiz Pardo, ÁlvaroAuthority UCA; Salmerón Lissén, José Manuel; Sánchez de la Flor, Francisco JoséAuthority UCA
Date
2024
Department
Ingeniería Mecánica y Diseño Industrial; Máquinas y Motores Térmicos
Source
Rincón-Casado, A., Rodríguez Jara, E. Á., Ruiz Pardo, A., Salmerón Lissén, J. M., & Sánchez de la Flor, F. J. (2024). Reducing the Cooling Energy Demand by Optimizing the Airflow Distribution in a Ventilated Roof: Numerical Study for an Existing Residential Building and Applicability Map. Applied Sciences (Switzerland), 14(15).
Abstract
This work presents a study of a ventilated hollow core slab system (VHCS) that obviates the need to completely replace the slab of an existing residential building. It is assimilated to a heat exchanger to allow its effectiveness to be studied as a function of the area and airflow rate. The balance between the energy consumed by the fan and the heat evacuated by the system is also studied through the use of the thermo-hydraulic performance factor (THPF), for which a series of cases were simulated by CFD following a methodology in which a configuration is achieved by means of the sequential analysis of cases in which both the thermal effectiveness and the THPF are maximized. The configuration chosen in this study was found to benefit from high airflow rates since, although this implies an increase in fan energy consumption, the increase in heat removed is proportionally greater. It has also been found that the design of the airflow distribution through the slab is of high importance as it affects both the heat exchanged with the slab and the pressure losses. An applicability map has been developed as a function of the temperature of the space below and the air temperature at the inlet of the ventilated roof. The heat flux per unit area that the studied envelope is able to evacuate is about 20 W/m2 K.
Subjects
ventilated hollow core slab systems; building retrofitting;; thermal efficiency; thermo-hydraulic performance factor; ventilated roof
Collections
  • Artículos Científicos [11777]
  • Articulos Científicos Ing. Mec. [320]
  • Articulos Científicos Maq. Mot. Térm. [108]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Browse

All of RODINCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Statistics

View Usage Statistics

Información adicional

AboutDeposit in RODINPoliciesGuidelinesRightsLinksStatisticsNewsFrequently Asked Questions

RODIN is available through

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Academic

Related links

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

Contact informationSuggestionsUser Support