Reducing the Cooling Energy Demand by Optimizing the Airflow Distribution in a Ventilated Roof: Numerical Study for an Existing Residential Building and Applicability Map

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/34751

DOI: 10.3390/APP14156596

ISSN: 2076-3417

Ficheros
2024 Reducing the Cooling Energy Demand by Optimizing the Airflow Distribution in a Ventilated Roof.pdf (40.03Mb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
Rincón Casado, AlejandroAutoridad UCA; Rodríguez Jara, Enrique ÁngelAutoridad UCA; Ruiz Pardo, ÁlvaroAutoridad UCA; Salmerón Lissén, José Manuel; Sánchez de la Flor, Francisco JoséAutoridad UCA
Fecha
2024
Departamento/s
Ingeniería Mecánica y Diseño Industrial; Máquinas y Motores Térmicos
Fuente
Rincón-Casado, A., Rodríguez Jara, E. Á., Ruiz Pardo, A., Salmerón Lissén, J. M., & Sánchez de la Flor, F. J. (2024). Reducing the Cooling Energy Demand by Optimizing the Airflow Distribution in a Ventilated Roof: Numerical Study for an Existing Residential Building and Applicability Map. Applied Sciences (Switzerland), 14(15).
Resumen
This work presents a study of a ventilated hollow core slab system (VHCS) that obviates the need to completely replace the slab of an existing residential building. It is assimilated to a heat exchanger to allow its effectiveness to be studied as a function of the area and airflow rate. The balance between the energy consumed by the fan and the heat evacuated by the system is also studied through the use of the thermo-hydraulic performance factor (THPF), for which a series of cases were simulated by CFD following a methodology in which a configuration is achieved by means of the sequential analysis of cases in which both the thermal effectiveness and the THPF are maximized. The configuration chosen in this study was found to benefit from high airflow rates since, although this implies an increase in fan energy consumption, the increase in heat removed is proportionally greater. It has also been found that the design of the airflow distribution through the slab is of high importance as it affects both the heat exchanged with the slab and the pressure losses. An applicability map has been developed as a function of the temperature of the space below and the air temperature at the inlet of the ventilated roof. The heat flux per unit area that the studied envelope is able to evacuate is about 20 W/m2 K.
Materias
ventilated hollow core slab systems; building retrofitting;; thermal efficiency; thermo-hydraulic performance factor; ventilated roof
Colecciones
  • Artículos Científicos [11777]
  • Articulos Científicos Ing. Mec. [320]
  • Articulos Científicos Maq. Mot. Térm. [108]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario