• español
    • English
  • Login
  • español 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Comunidades y colecciones
Ver ítem 
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

A New Design for Reference Values Assignment in Proficiency Testing for Fat and Crude Protein in Raw Milk for a Limited Number of Participants

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/35741

DOI: 10.3390/foods13172693

ISSN: 2304-8158

Ficheros
OA_2024_1069.pdf (3.082Mb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
Poo, S.; Palma Lovillo, MiguelAutoridad UCA; Muñoz, Ociel
Fecha
2024-08-26
Departamento/s
Química Analítica
Fuente
Foods, Vol. 13, Núm. 17, 2024
Resumen
Proficiency testing (PT) allows food laboratories to endorse their competency to provide food safety guarantees to producers and consumers. One of the recommended methods for assigning reference values in PT with a small number of participants consists in considering the results that a laboratory obtains by means of a calibration test based on certified reference material (CRM). The present study delves into the results from eight PT rounds on the determination of fat and crude protein from raw milk, with modifications in the number of samples and the analysis sessions from that required by the ISO 13528:2022. The uncertainty criterion of the assigned value established by the ISO 13528:2022 standard was met by 93% of the participating laboratories, which allowed most participants to be evaluated through z-score. The assigned values were generally compatible with the results obtained by the participants. Thus, it can be concluded that the design for the assignment of the reference value is appropriate for PT with a limited number of participants. It is recommended for future PT to limit the uncertainty of the CRM according to their availability and to update the standard deviation of the proficiency assessment for the Mid-Infrared Spectroscopy method (MIR).
Materias
proficiency testing; reference value; assigned value; reduced number of laboratories; raw milk; fat; crude protein
Colecciones
  • Artículos Científicos [12006]
  • Artículos Científicos IVAGRO [733]
  • Articulos Científicos Quim. Ana. [398]
Atribución 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Atribución 4.0 Internacional

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario