Biomechanical Analysis of Non-Metallic Biomaterial in the Manufacture of a New Knee Prosthesis

Ficheros
Estadísticas
Métricas y Citas
Metadatos
Mostrar el registro completo del ítemFecha
2021-10Departamento/s
Ingeniería Mecánica y Diseño IndustrialFuente
Materials 2021, 14(20), 5951Resumen
The increase in the number of revision surgeries after a total knee replacement surgery
reaches 19%. One of the reasons for the majority of revisions relates to the debris of the ultra-high
molecular weight polyethylene that serves to facilitate the sliding between the femoral and tibial
components. This paper addresses the biomechanical properties of ULTEMTM 1010 in a totally new
knee replacement design, based on one of the commercial models of the Stryker manufacturer. It is
designed and produced through additive manufacturing that replaces the tibial component and the
polyethylene in such a way as to reduce the pieces that are part of the prosthetic assembly to only two:
the femoral and the tibial (the so-called “two-component knee prosthesis”). The cytotoxicity as well
as the live/dead tests carried out on a series of biomaterials guarantee the best osteointegration of the
studied material. The finite element simulation method guarantees the stability of the material before
a load of 2000 N is applied in the bending angles 0 , 30 , 60 , 90 , and 120 . Thus, the non-metallic
prosthetic material and approach represent a promising alternative for metal-allergic patients.
Materias
non-metallic knee prosthesis; ULTEMTM 1010 biomaterial; additive manufacturing; biomechanical design; two-component knee prosthesis; live/deadColecciones